Raypak Power Vent D2 Especificações

Consulte online ou descarregue Especificações para Componentes para dispositivos de segurança Raypak Power Vent D2. Raypak Power Vent D2 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 13
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
OPERATING AND
INSTALLATION
INSTRUCTIONS
Models
181/182, 260/261, 330/331, 400/401
Water Heaters and Boilers
D-2 POWER VENT
CATALOG NO. 6000.57E
Effective: 05-20-08
Replaces: 10-26-06
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids or other combustible
materials in the vicinity of this or any other appliance. To do so may result in an explosion
or fire.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Refer to the user’s information manual
provided with this heater. Installation and service must be performed by a qualified in-
staller, service agency or the gas supplier.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas
suppliers instructions.
· If you cannot reach your gas supplier, call the fire department.
This manual should be maintained in legible condition and
kept adjacent to the appliance or kept in a safe place for
future reference.
P/N 241086 Rev. 6
Vista de página 0
1 2 3 4 5 6 ... 12 13

Resumo do Conteúdo

Página 1 - D-2 POWER VENT

OPERATING ANDINSTALLATIONINSTRUCTIONSModels181/182, 260/261, 330/331, 400/401Water Heaters and BoilersD-2 POWER VENTCATALOG NO. 6000.57EEffective:

Página 2

Dimensional DataModel A B C D181 18.13 12.38 7.88 4.25182 18.13 12.38 7.88 4.25260 18.13 12.38 7.88 4.25261 18.13 12.38 7.88 4.25330 17.50 15.75 7.63

Página 3

START UP PROCEDURESThe water system, the gas system and theelectrical system for the heater should becompleted and checked as per the heaterinstallati

Página 4

ILLUSTRATED PARTS LIST12123456789101112131415

Página 5

Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725Litho in U.S.A.www.raypak.com

Página 6

MODEL MINIMUM KIT FACTORYSIZE CONNECTION NUMBER WIREDDIAMETER182/181 4” 008757 120V260/261 4” 008757 120V330/331 4” 008758 120V400/401 4” 008758 120VP

Página 7

33. INSTALLATION REQUIREMENTSThe equipment must be installed in accordance with local codes, or in the absence of local codes with thelatest edition o

Página 8 - 182-260 H4/WH1 (ATMOSPHERIC)

4WIRING A POWERVENT ASSEMBLY TO AN APPLIANCE WITH IID IGNITION.WARNING: Disconnect all electrical power to the unit before servicing to avoid potentia

Página 9 - 181-261 H4/WH1 (Low NOx)

VENTINGThe vent pipe must be the same size or larger than what is indicated. The D-2 Power Vent iscapable of 360-degree discharge rotation and operat

Página 10 - SEQUENCE OF OPERATION

6Minimum Clearances from Vent/Air Inlet Terminations - Indoor and Outdoor InstallationsVent/Air Inlet Termination Clearances

Página 11

7The Raypak Power Vent operates with a positive vent static pressure and with a vent gastemperature that avoids excessive condensate production in the

Página 12 - ILLUSTRATED PARTS LIST

8 182-260 H4/WH1 (ATMOSPHERIC)

Página 13 - Litho in U.S.A

181-261 H4/WH1 (Low NOx)9

Comentários a estes Manuais

Sem comentários